Pole-mounted SF6 Load Breaker Switch is a pole-mounted SF6 load breaker switch that uses sulfur hexafluoride (SF6) gas as an insulating medium and an arc extinguishing medium. This switchgear is used in medium voltage power systems and is particularly suitable for applications where the circuit needs to be shut off under load current conditions

Product Description

General

The LRFW series outdoor SF6 load switch is a three-phase AC 50Hz /60Hz outdoor medium-voltage switchgear, which can break off and close the load current and overload current in the power system; The load switch is equipped with intelligent controller to realize the automation of distribution system.

Service and Installation Conditions

  • height above sea level:≤3000m
  • Air temperature:-40℃~+50℃

Maximum diurnal temperature difference:≤25 ℃

  • Relative humidity:Daily mean 95% monthly average 90%
  • Maximum wind speed:≤34m/s
  • Earthquake intensity:<8 degree
  • Icing thickness:<10mm
  • Thickness of snow:<35mm
  • Irradiance:<1W/cm2
  • Pollution grade:Ⅲclass、Ⅳclass
  • Installation site:No fire disaster, explosion danger, chemical corrosion and frequent  strenuous vibration places

Specifications

Item Unit Data
Rated voltage kV 12 24 36
Rated frequency Hz 50/60
Rated current A 400 / 630
Rated short-circuit withstand/breaking current kA 12.5
Rated short-circuit making current (peak) kA 31.5
Rated peak withstand current kA 31.5
Rated short-circuit time Sec 1
Power Operating Time (Close/Open) Sec <2
Mechanical Operations Times 5000
Rated full load operations Times 400
Power frequency withstand voltage (1 min) kV 28/32 50/60 70/80
Lightning impulse withstand voltage (peak) kV 76/85 125/145 170/190
IP Level 65
Arc Extinction Medium Times SF6 Gas
Insulation Medium SF6 Gas
SF6 gas year leak rate ≤0.5%

Product Advantages

  • 1.Safety: SF6 is flammable and explosive, and the use of load circuit breakers can prevent any possible fire accidents.
  • 2.Reliability: The circuit breaker is designed for high reliability and can work stably in extreme environments.
  • 3.Flexibility: It can cope with various load situations and adapt to different power supply needs.
  • 4.Easy maintenance: Usually the load circuit breaker has a remote control system for easy maintenance and inspection.
  • 5.Environmental protection: Systems using SF6 gas can correctly cut off the power supply in the event of a failure, reducing the impact on the environment.
  • 6.Durability: Circuit breakers usually have a long life and can last for many years.

Application Places

First, urban power grid
Distribution boxes, substations and other places in urban power grids usually need to use sulfur hexafluoride circuit breakers for control and protection of power equipment. The sulfur hexafluoride load switch has the characteristics of explosion-proof and durability, which can ensure the normal operation of the power system, reduce the loss and impact caused by power failures, and ensure the stable supply of power in the city. Second, industrial and mining enterprise power grid
Industrial and mining enterprises usually need to use high-power power equipment, and the control, protection and management of these equipment need to use hexafluoride load switches. In the harsh environment such as high temperature, high humidity and corrosion, the hexafluoride load switch has excellent protection and durability, which can ensure the safe operation of the equipment and improve the production efficiency and economic benefits of industrial and mining enterprises.
Third, the railway traffic grid
Railway traffic network needs to use a lot of power equipment, including traction transformer, traction frequency converter and so on. The sulfur hexafluoride load switch can provide a variety of application methods, which can realize emergency power failure, overload protection and other functions to ensure the operation of power equipment and the normal operation of trains. At the same time, the sulfur hexafluoride load switch has the characteristics of compact and small size, which can adapt to the high-density installation of electrical equipment.

Packing

Download

Product Video

Play Video

Faq

  • What are the applications and advantages of SF6 in electrical equipment?

    Use

    1.Insulation

    Because sulfur hexafluoride does not come into contact with wires and has very high insulation strength, electronic devices can be guaranteed to work safely under high voltage conditions.

    2. Put out the fire

    Sulfur hexafluoride has amazing fire-fighting performance, and in a fire, it can effectively nip the fire in the bud, so as to avoid the expansion of the fire causing greater damage to the equipment.

     Advantages

    1. Non-flammable

    Because sulfur hexafluoride is an inert gas that does not burn or spontaneously ignite, it is difficult to ignite at high temperatures or high voltages.

    2. Good thermal conductivity

    Sulfur hexafluoride has good thermal conductivity and can effectively dissipate heat in high temperature or high pressure environments, thus ensuring stable operation of equipment.