LBS type Outdoor on load break switch (switch disconnector ) contained in this list are destined to switch stub lines and ring main lines or transformers( lt can be equipped with MV HRG fuse links as short circuit protection function)or for switching under on load conditions. LBS type switch comply with lEC/lEEE and DVE-recommendation standards.Especially comply with DIN VDE 0670 part 3 and lEC publication lEC-60265,IEC-129.

Product Description

Product Overview

The Pole-mounted Load Breaker Switch is a versatile switchgear designed for pole-top installation, primarily used for making and breaking load currents. It is also capable of switching off and closing specific voltage no-load transformers and no-load electrical lines. Suitable for systems with a rated voltage of 10kV and AC 50Hz, this switchgear can be equipped with either manual or electric operation mechanisms, making it an advanced and reliable choice for outdoor terminal protection on 10kV lines.

Structural Features

The Pole-mounted Load Breaker Switch incorporates a spring-operating mechanism, which supports both electric and manual switching operations, aligning with the operational characteristics of domestic power systems. The secondary current of the current transformer is standardized to 5A and can be configured in multiple groups with variable voltage ratios to accommodate diverse requirements for relay protection, telemetry, and measurement. The switch itself typically includes an isolation switch, and both the breaker and the isolation switch are equipped with operating locks to ensure safe and secure operation.

Installation Method

The installation of the Pole-mounted Load Breaker Switch should be carried out by qualified personnel following the manufacturer’s guidelines. It is designed for pole-top installation, ensuring accessibility for operation and maintenance. The installation process should consider:

  • Ensuring the switch is securely fastened to the pole to withstand environmental conditions.
  • Verifying that the operating mechanisms are correctly aligned for smooth operation.
  • Confirming that all electrical connections are properly made to prevent any operational issues.

Applicable Environment Conditions

The Pole-mounted Load Breaker Switch is designed to operate under the following environmental conditions:

  • Air Temperature: The switch can withstand a maximum temperature of +75°C and a minimum temperature of -45°C.
  • Humidity: It is suitable for environments with a monthly average humidity of 95% and a daily average humidity of 90%.
  • Altitude: The maximum installation altitude is 2500 meters above sea level.
  • The ambient air should not be significantly polluted by corrosive or flammable gases or vapors.
  • The area should not be subject to frequent violent vibrations.

 

 

Specifications

ltem Unit Data
Rated voltage kV 12 24 36
Rated frequency Hz 50/60
Rated current A 200/400/630
Rated short circuit withstand current(IS) kA 20
Rated peak withstand current(IS) kA 50
Rated making current kA 31.5-50
Rated insulation leve(HV) Lightning impulse kA 75/85 125/145 170/195
Power frequency withstand 45 55/75 75/100
Rated short circuit breaking capacity cos.∅(0.7) Without maintenance of contacts
For active circuits 20breakings A 630 630 400
30breakings 400 400 300
4Obreakings 300 300 250
50breakings 250 250 170
75breakings 170 170 160
120breakings 110 110 110
200breakings 65 65 65
280breakings 50 50 50
For ring circuits A 630 400 250
Rated breaking capacity of transformer A 50
Rated breaking capacity of cable charging A 11
Rated breaking capacity of earthing fault A 56

Note: The LBS type on load break switch (Switch disconnector) is equipped with stored energy released by fuse strike pins. The stored energy mechanism for the opening oparation is relaased by fuse strike pins.

The trip actuator is mounted on top of the fuse contact clip.

The DIN type fuse is held in spring type contacts, secured by a tal lever. All the components are made of stainless steel, to preventcorrosion, have Jong live, and in the reset position, The trip lever is parked in an over-centre position.

Product Advantages

  • 1.Compact design
    2.All steel parts either in stainless steel or hot-dip galvanized
    3.Solid and stable base frame
    4.Main contact with icing protection
    5.Insulators available in porcelain or alternatively in silico ne
    6.Minimal sag for the line-connection thanks to the two fixed terminals
    7.Completely maintenance antirust AL alloy -Arc chamber
    8.Switching-off procedure without external arc
    9.Short circuit making capacity under specific conditions possible
    10.Fixing on the supporting structure either by clamping (free setting) or screwing (holes in the base frame)
    11.Easy on-siteinstallation and setting
    12.High reliability: up to 1 ‘000 cycles (depending on the making current)
Pole-mounted Load Breaker Switch

Application Places

Column switches are widely used in various power systems, especially in high-voltage substations and power transmission and distribution systems. Here are some application scenarios for the on-column switch:
1. Switchgear: In high-voltage substations, column switches are often used in various switchgear for controlling, switching or distributing circuits. For example, some medium voltage switchgear, isolation switch, etc., need to use the column switch to achieve control and protection.
2. Power capacitor: Power capacitor is a device used to improve the power factor of the grid, most of which also need to be controlled and protected by using on-column switches.
3. Distribution network: In the power transmission and distribution network, the column switch is also a very important control device, which can well protect the distribution network from overcurrent and short circuit damage

Packing

Download

Product Video

Play Video

Faq

  • 1. What is a Pole-mounted Load Breaker Switch?

    It’s an outdoor switchgear designed for pole-top installation, used for controlling and protecting 10kV AC power systems by making and breaking load currents.

  • 2. What is the temperature range for the switch to operate properly?

    The maximum operating temperature is +75°C, and the minimum is -45°C.

  • 3. Are there common issues users should be aware of?

    Common issues may include mechanical failures, corrosion, or environmental damage. Regular inspections and maintenance can help prevent these.

Related Products

Get in Touch With Us

CHOOSE YOUR LANGUAGE
TYPE TO SEARCH
Contact Now
How would you like to be contacted?
* We respect your privacy. When you submit your contact information, we agree to only contact you in accordance with our Privacy Policy.