Product Introduction:
Fuse Links are vital electrical protection components designed to safeguard circuits from damage due to overcurrent conditions. They operate by melting and breaking the circuit when the current exceeds a specified threshold, thus preventing potential hazards.
Product Details:
Structural Features:
Installation Process:
Applicable Environmental Conditions:
Technical Charaacteristics
Table 1 – melting current for type – K (fast) fuse links (A)
| Rated current | 300-or 600 Second Melting Current | 10 Second Melting Current | 0.1 Second Melting Current | Speed Ratio | |||
|---|---|---|---|---|---|---|---|
| Min | Max | Min | Max | Min | Max | ||
| 2 | 4 | 4.8 | – | 10 | – | 58 | – |
| 4 | 8 | 9.6 | – | 10 | – | 58 | – |
| 6 | 12 | 14.4 | 13.5 | 20.5 | 72 | 86 | 6.0 |
| 10 | 19.5 | 23.4 | 22.5 | 34 | 128 | 154 | 6.6 |
| 16 | 33 | 40 | 39.5 | 58.5 | 230 | 275 | 6.9 |
| 25 | 50 | 60 | 60 | 90 | 350 | 420 | 7.0 |
| 31.5 | 66 | 80 | 81 | 120.5 | 469 | 573 | 7.1 |
| 40 | 80 | 96 | 96 | 146 | 565 | 680 | 7.1 |
| 50 | 101 | 121 | 126 | 188 | 719 | 862 | 7.1 |
| 80 | 160 | 192 | 205 | 307 | 1180 | 1420 | 7.4 |
| 100 | 200 | 240 | 258 | 388 | 1520 | 1820 | 7.6 |
Table 2 – melting curent for type – T(slow) fuse links(A)
| Rated current | 301-or 600 Second Melting Current | 10 Second Melting Current | 0.1 Second Melting Current | Speed Ratio | |||
|---|---|---|---|---|---|---|---|
| Min | Max | Min | Max | Min | Max | ||
| 2 | 4 | 4.8 | – | 11 | – | 100 | – |
| 4 | 8 | 9.6 | – | 11 | – | 100 | – |
| 6 | 12 | 14.4 | 15.3 | 23 | 120 | 144 | 10 |
| 10 | 19.5 | 23.4 | 26.5 | 40 | 224 | 269 | 11.5 |
| 16 | 33 | 40 | 47.5 | 71.5 | 413 | 497 | – |
| 25 | 50 | 60 | 73.5 | 109 | 635 | 762 | 12.7 |
| 31.5 | 66 | 80 | 98 | 149 | 852.5 | 1023 | 12.9 |
| 40 | 80 | 96 | 120 | 178 | 1040 | 1240 | 13 |
| 50 | 101 | 121 | 152 | 226 | 1310 | 1570 | 13 |
| 80 | 160 | 192 | 248 | 370 | 2080 | 2500 | 13 |
| 100 | 200 | 240 | 319 | 475 | 2620 | 3150 | 13.1 |
1.Dropout Fuse Cutouts: Fuse links are used in dropout fuse cutouts to protect distribution transformers and lateral distribution lines. When a fault occurs, the fuse link melts, causing the fuse holder to drop out and visibly indicate a fault, which facilitates easy identification and replacement.
2. Distribution Panels: Fuse links are commonly used in distribution panels to protect individual circuits from overcurrent conditions, ensuring the safety and reliability of electrical installations in residential, commercial, and industrial settings.
3. Transformers: Fuse links are used to protect transformers from overloads and short circuits, preventing damage to the transformer windings and associated equipment.
4. Motor Protection: Fuse links provide protection for electric motors against overcurrent and short circuits, safeguarding the motor windings and extending the life of the motor.
5. Capacitor Banks: Fuse links are employed to protect capacitor banks used for power factor correction, preventing damage due to overcurrent conditions.
6. HVAC Systems: Fuse links are used in heating, ventilation, and air conditioning (HVAC) systems to protect compressors, fans, and other components from overcurrent and short circuit faults.
7. Power Distribution Networks: Fuse links are used in power distribution networks to protect overhead and underground distribution lines, isolating faulted sections and minimizing the impact on the overall network.
8. Control Panels: Fuse links are used in control panels to protect various control devices, ensuring reliable operation and preventing damage to sensitive components.
9. Renewable Energy Systems: Fuse links are used in renewable energy systems, such as solar photovoltaic (PV) installations and wind turbines, to protect the system components from overcurrent and short circuits.
10. Battery Storage Systems: Fuse links are used in battery storage systems to protect battery banks and associated power electronics from overcurrent conditions, ensuring safe and reliable operation.
11. Lighting Circuits: Fuse links are used to protect lighting circuits from overcurrent, preventing damage to fixtures and reducing the risk of fire.
These applications demonstrate the versatility and importance of fuse links in ensuring the protection and reliability of various electrical systems.


A fuse link is a protective device used in electrical circuits to prevent overcurrent, including overloads and short circuits. It consists of a metal wire or strip that melts when the current exceeds a specific level, interrupting the electrical flow.
A fuse link operates by melting its metal wire or strip when the current passing through it exceeds a predetermined threshold. This melting action interrupts the circuit, stopping the flow of electricity and protecting the connected equipment from damage.
To select the right fuse link, consider the following factors: operating voltage, current rating, interrupting capacity, time-current characteristic, and the specific requirements of the application. Consulting manufacturer datasheets and guidelines is also essential.
A fuse link is a one-time-use device that melts and must be replaced after operating. A circuit breaker, on the other hand, can be reset and reused multiple times after tripping due to overcurrent conditions. Fuse links are typically simpler and cheaper, while circuit breakers offer more convenience and advanced features.
Yes, fuse links can be used in both AC and DC circuits, but it is important to ensure that the fuse link is rated for the specific type of circuit. The characteristics of AC and DC circuits differ, so using the appropriate fuse link is crucial for effective protection.
If a fuse link blows frequently, it may indicate an underlying problem such as an overloaded circuit, a short circuit, or faulty equipment. Investigate the cause of the overcurrent condition and address it before replacing the fuse link. Using a fuse with a higher rating is not recommended, as it can compromise protection.
Many fuse links provide a clear visual indication when they have operated, such as a melted wire visible through a transparent casing or a drop-out mechanism in dropout fuse cutouts. Additionally, using a multimeter to check for continuity can confirm if a fuse link has blown.
A dropout fuse cutout is a type of fuse holder used in power distribution systems. It contains a fuse link that, when blown, causes the fuse holder to drop out and hang visibly. This provides an easy and visible indication of a fault, facilitating quick identification and replacement.
To safely replace a blown fuse link, follow these steps: